Relay RPVn

Relay RPVn is an electromagnetic, polarized, high-frequency, bistable, two-position relay with break or change-over contacts and a circuit double-break; designed for switching electrical circuits in a current-free mode with frequency to 80Hz.

Ordering data:

Relay RPVn ИТНЯ 647619.018 ИТНЯ 640171.006 ТУ.

Download pdf

Models

Table 1

2

3

4

5

6

Size

Switching Mode

Mounting Type

Control-Circuit Voltage, V

Allowable Values of

U and I when F=1,5 MHz

1

10х6х6

1

Change-over 4 contacts

 

1

Through Holes

1

3V

1

800V, 2A

2

15х10х10

2

5V

2

1500V, 5A

3

25х15х14

2

Change-over 6 contacts

2

Surface Mounting

3

10V

3

3000V,10A

3

Through Holes and Three-Dimensional Wiring

4

12V

4

5000V,15A

4

35х21х24,5

3

Break

5

27V

5

4000V,30A

Table 2

Operating Conditions

Allowable Values of Effective Voltage on  Open Contacts and Allowable Values of Current Flowing through Energized Contacts on Frequency of 1,5 MHz, not more

Relay Codes

11121,11141,11221,
11241,12121,12141
12221,12241,13121,
13141,13221,13241

21132,21142,21232,
21242,23132,23142,
23232,23242

31343,31353,
33343,33353

41344,41345,
41354,41355,
43344,43345,
43354,43355

Contact-Contact

Contact-Coils

Contact-Contact

Contact-Coils

Contact-Contact

Contact-Coils

Contact-Contact

Contact-Coils

Normal Climate Ratings

Urms
kV

1

0,8

1,5

1,2

3

2,5

5

4

Irms
A

2

-

5

-

10

-

15

-

High Humidity, Silver Thaw, Dew

Urms
kV

1

0,8

1,5

1,2

3

2,5

5

4

Irms
A

2

-

5

-

10

-

15

-

Technical Parameters

Table 3

Relay Code

Rated Voltage, V

Operating Ambient Temperature,°С

Air Pressure

Time of Continuous Energized Coil Standing at Maximum  Ambient Temperature, ms

Pulse Ratio, not less

Total Time of Continuous Energized Coil Standing at Maximum Ambient Temperature, ms

Pa

mm of Mercury

11121, 11221,
12121, 12221,
13121, 13221

 

-50°С +70°С

10,7∙104
-
6∙104

800-450

2

10

27,7

11141, 11241,
12141, 12241,
13141, 13241

21132,  21232
23132,  23232

3

7

41,6

21142,  21242
23142,  23242

31343, 33343

5

6

69,4

31353, 33353

41344,41345
43344,43345

10

5

138,8

41354, 41355
43354, 43355

Technical Specifications

Table 4

Operating Time, not more, ms

5

Release Time, not more, ms

3

Rated Control Winding Voltage, V

12, 27

Operation Contact Resistance, Ohm

0,05

Switching Frequency, Hz

30

Number of Switching Cycles

5·107

Insulation Resistance, mOhm:
     at Normal Climate Ratings
     at High Humidity, Silver Thaw, Dew

     

200
50

Test AC Voltage with Frequency of 50Hz between High-Frequency Current-Carrying  Circuits and Coil, V:
           at Normal Climate Ratings
           at High Humidity, Silver Thaw, Dew

           

 

180
6000

Weight, g, Depending on Model

1…15

Storage Ability  at Ɣ=95%, Year, not less

15

Download pdf